RO Membranes
Our RO membranes are the produced from high quality elements which is applicable from light commercial use to drinking water industries. The RO membranes are checked to meet the set standard test level (high performance count) to ensure that customer will get both highest quality water and rejection rates.
The RO membranes technologies of the filtration system will remove large molecules and ions from the solutions that flows through to membranes stages. The results obtained is that the solute to retained on the pressurized side, and pure solvent to pass through the pores on the other side of the membrane elements to ensure high purification output. (Please refer to the specification and performances per attached data) And this is the reason why our selected RO membranes are the very consumable, economical plus cost effectiveness and mostly used with the water treatment filtration process.
Application Areas:
-
Drinking water / Beverages Industries
-
Pharmaceuticals & Cosmetics Industries
-
Chemicals Industries
-
Food Processing Industries
-
Electronics Industries
-
Water Treatments Plants
-
Brackish Water |
|
|
|
RO Membranes Product’s Features & Content
Types: Spiral Wound Membrane Polymer: Composite Polyamide Brine spacer Material: Polypropylene
Specification and Performances
RO Membranes Size (inch) |
Salt Rejection Rates % |
Permeate Flow GPD |
a) 2.5 x 14 |
99.4 |
160 |
b) 2.5 x 21 |
99.4 |
330 |
c) 2.5 x 40 |
99.4 |
650 |
d) 4.0 x 14 |
99.4 |
525 |
e) 4.0 x 21 |
99.4 |
900 |
f) 4.0 x 40 |
99.5 |
2300 |
g) 8.0 x 40 |
99.5 |
10000 |
h) 8.0 x 40 |
99.5 |
11000* |
Testing Conducts Results (Normal Operating Condition)
For RO Membrane (sizes range: a, b, c, d, e)
NaCl Solution |
Pressure |
Temperature |
pH range |
Permeate Recovery % |
1500 ppm |
225 psi (15.5 bar) |
25 C / 77 F |
6.5 – 7.0 |
10 |
For RO Membrane (size range: f, g, h)
NaCl Solution |
Pressure |
Temperature |
pH range |
Permeate Recovery % |
1500 ppm |
225 psi (15.5 bar) |
25 C / 77 F |
6.5 – 7.0 |
15 |
For RO Membrane Size: h (Maximum Operating Condition)*
Operating Pressure |
Temperature |
Pressure Drop |
Feed Flow |
Chlorine Concentrate |
600 psi (41bar) |
45 C / 113 F |
10 psi (0.7 bar) |
75 gpm (17m/h) |
<0.1 ppm |
Packing Condition: RO Membrane 1 piece (wrap / with side cover protection foam) / Carton (Weight varies according to the membrane sizes)
|